• Users Online: 68
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2022  |  Volume : 19  |  Issue : 3  |  Page : 146-152

Orbital floor reconstruction using prebent titanium mesh or polyetheretherketone patient-specific implant: Comparative study


Department of Oral & Maxillofacial Surgery, Faculty of Dentistry, Tanta University, Tanta, Egypt

Correspondence Address:
Maram N Breshah
PhD, Department of Oral & Maxillofacial Surgery, Faculty of Dentistry, Tanta University, Tanta
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/tdj.tdj_14_22

Rights and Permissions

Purpose This study was planned to compare between polyetheretherketone patient-specific implant and prebent titanium mesh in orbital floor reconstruction. Patients and methods Twelve patients with unilateral orbital floor fracture indicated for reconstruction divided in two equal groups according to the type of implant used. Postoperative evaluation was done for 6 months. Patients of both groups were examined clinically for hypoglobus, enophthalmos, ocular motility and diplopia and radiographically for orbital volume measurement preoperatively and postoperatively. A comparative analysis of the treatment outcomes was performed. Results Significant improvement in the external appearance of the eye including hypoglobus, enophthalmos, and ocular motility and diplopia although group II showed one (16.7%) patient with persistent hypoglobus, one (16.7%) patient measured as grade 3 enophthalmos (>2 mm), one (16.7%) patient with marked limitation of ocular motility (grade 3) and diplopia. There was significant improvement in the orbital volume of the affected side in both groups with no significant difference postoperatively between both groups during different follow up periods. There was significant difference between the orbital volume of the affected and nonaffected sides preoperatively and the difference between them was 3.91 ± 0.92 cm3 for group I and 3.64 ± 1.29 cm3 for group II which markedly decreased postoperatively was 0.50 ± 0.72 cm3 for group I and 1.35 ± 0.86 cm3 for group II with no significant difference between affected and nonaffected eyes. Conclusion The results of this study showed that polyetheretherketone patient-specific implant is precise, predictable, and demonstrated higher clinical efficacy in comparison to prebent titanium mesh in orbital floor reconstruction. Preformed prebent titanium mesh is not preferred in large defects.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed414    
    Printed36    
    Emailed0    
    PDF Downloaded60    
    Comments [Add]    

Recommend this journal