• Users Online: 74
  • Home
  • Print this page
  • Email this page
Home About us Editorial board Ahead of print Current issue Search Archives Submit article Instructions Subscribe Contacts Login 
ORIGINAL ARTICLE
Year : 2016  |  Volume : 13  |  Issue : 4  |  Page : 193-198

The effect of changes in the intermaxillary distance in mandibular advancement splints as a treatment of obstructive sleep apnea


1 Department of Prosthodontics, Faculty of Dentistry, Tanta University, Tanta, Egypt
2 Department of Otolaryngology, Faculty of Medicine, Tanta University, Tanta, Egypt

Correspondence Address:
Rehab M Abdallah
Department of Prosthodontics, Faculty of Dentistry, Tanta University, Tanta
Egypt
Login to access the Email id

Source of Support: None, Conflict of Interest: None


DOI: 10.4103/1687-8574.195711

Rights and Permissions

Objective To evaluate the effect of intermaxillary space variation induced by mandibular advancement splints (MAS) constructed with three different interocclusal distances on the efficacy of the treatment of the obstructive sleep apnea. Materials and Methods Ten patients were selected after polysomnography from the Sleep Laboratory in Tanta University. At the beginning of the study all patients were asked to complete the Epworth sleepiness scale and after the treatment period. Each patient received three MAS constructed with intermaxillary distance of 4, 8, and 10 mm and patients were recalled after 4-6 weeks for follow-up study using nasopharyngoscopy and polysomnogram after each appliance. The patients were instructed to withdraw and stop the use of their appliance for at least 1 week before using the next appliance. The recorded data for each patient with the three appliances were collected, tabulated and statistically analyzed using t-paired test and Friedman's test. Results There was statistically significant difference between the baseline records and the records obtained after the use of each MAS appliance (P < 0.05). Conclusion The use of MAS appliance with increased vertical dimension improved the velopharyngeal caliper and improvement in the polysomnographic variables especially Apnea/Hypopnea Index, sleep efficiency and Arousal Index was observed.


[FULL TEXT] [PDF]*
Print this article     Email this article
 Next article
 Previous article
 Table of Contents

 Similar in PUBMED
   Search Pubmed for
   Search in Google Scholar for
 Related articles
 Citation Manager
 Access Statistics
 Reader Comments
 Email Alert *
 Add to My List *
 * Requires registration (Free)
 

 Article Access Statistics
    Viewed2911    
    Printed220    
    Emailed0    
    PDF Downloaded222    
    Comments [Add]    
    Cited by others 1    

Recommend this journal